*Untuk maklumat lanjut produk, semak maklumat di bawah atau hubungi kami terus
MAKLUMAT PESANANOEM | |
Pengeluar | Bahagian OEM |
Ditipu | 3313-C |
Covidien > Nellcor | MAX-I, MAX-II |
Draeger | MX50067 |
GE Healthcare > Marquette | 70124026 |
Mindray > Datascope | 0010-10-12204 |
Sage | DP063X-09M |
Stryker > Medtronic > Physio Control | 11996-000115 |
Keserasian: | |
Pengeluar | Model |
Baxter | Penjelajah, Raja |
Biolight | M9500, Siri Q, Q3, Q5, Q7 |
Biosys | BPM-200, SENTRY |
CAS Med | 511 |
Covidien > Nellcor | N-10, N-180, N-190, N-20, N-30, N-560, N-600, N-600x, N-65, N-85, NPB-190, NPB-195, NPB- 3910, NPB-3920, NPB-3930, NPB-3940, NPB-40, NPB-4000, NPB-75, PM100N, PM10N, Penderia yang mempunyai Teknologi Nellcor OxiMax dan 9 pin |
Criticare | 506DNV3, 506DNVP3, 506LNV3, 506LNVP3, 506NV3, 506NVP3 |
DRE | ASM 5000, Waveline, Waveline Plus |
Digicare | LW600 |
Draeger | Infinity Delta, Infinity Delta XL, Infinity Kappa, Narkomed 6400 |
Fukuda Denshi | Dinaskop DS-7100, LX-7230N |
GE Healthcare > Critikon > Dinamap | B105, B125, Carescape B650, Carescape V100, Compact DINAMAP MPS, E-NSAT, Pro 1000, Pro 1000 V3, Pro 200, Pro 300, Pro Series V2, ProCare 200, ProCare 400, ProCare Ausculatory 400 |
GE Healthcare > Marquette | Dash 2500, Dash 3000, Dash 4000, Dash 5000, Modul PDM, Procare B40, Solar 8000, Solar 8000M, Tram 451, i/9500 |
Goldway | Vet 420A, Vet 600A |
Medtronic > Covidien | Capnostream 35 (PM35MN) |
Tanda tengah > Cardell | 9403, 9405, 9500 Series, 9500HD, MAX-12 Duo HD |
Mindray > Datascope | Accutorr Plus, BeneView T1, BeneVision N1, DPM5, DPM6, DPM7, Duo, Pakar, Pasport, Pasport 12, Pasport 2, Pasport 8, Pasport V, Pasport XG, Spectrum, Spectrum OR, Trio, V-Series, VS 8, VS 8A, VS 8C, VS 9, VS 9A, VS 9C, ePM 10M, ePM 12M, iMEC 10, iMEC 12, iMEC 15, iMEC 15S, iMEC 5, iMEC 6, iMEC 7, iMEC Siri 8, iPMME 9800 |
Mortara | Juruukur S12/S19 |
Omron > Colin | BP-S510, T105NXM |
Philips | FM20, FM30, Heartstream XL, IntelliVue, IntelliVue FAST-SpO₂, IntelliVue MP2, IntelliVue MP70, IntelliVue MX450, M1020B, M2601A, M3000A, M3001A, M3001A A02, M301A, M301A, M301A 01A A02C18, M3001A A04, M3001A A04C06, M3001A A04C12, M3001A A04C18, M3002A, M3002A MMS X2, M3500B, M4735A, M8102A, M8102A MP2, M8105A MP5, M8105AS, M… Lihat Lagi |
Perubatan Smiths > BCI | 3100, 3101, 3180, 3300, 3301, 3302, 3303, 3304, 3401, 6100, 9100, Penasihat, Autocorr, Mini Torr, Mini Torr Plus |
Spacelabs | Ultraview SL, Ultraview SL 2700 |
Stryker > Medtronic > Physio Control | Lifepak 12, Lifepak 15 |
Welch Allyn | 1500, 42NT0-E1 LXi, 52N00, 52N0P, 52NT0, 52NT1, 53N00, 53N0P, 53NT0, 53NTP, 64NTPE-B, 64NTPX-2, 64NTPX-3, 64NTPX-3, 64NTPX-3 64NTPX-7 , 64NTPX-A, 64NTPX-B, 64NTPX-N, 64NTPX-Y, 64NTXE-B, 64NTXX-2, 64NTXX-3, 64NTXX-4, 64NTXX-5, 64NTXX-6, 64NTXX-7, 64NTXX-7, 64NTXX-7, 64NTXX-7, 64NTXX-7 -B, 64NTXX-N, 64NTXX-Y, 64NXPE-2, 64NXPE-3, 64NXPE-4, 64NXPE-5, 64NXPE-6, 64NXPE-7, 64NXPE-A, 64NXPE-B, 64NXPE-B, 64NXPE-X, 64NXPE-X , 64NXPX-2, 64NXPX-3, 64NXPX-4, 64NXPX-5, 64NXPX-6, 64NXPX-7, 64NXPX-A, 64NXPX-B, 64NXPX-N NXXE -4, 64NXXE-5, 64NXXE-6, 64NXXE-7, 64NXXE-A, 64NXXE-B, 64NXXE-N, 64NXXE-Y, 64NXXX-2, 64NXXX-3, 64NXXX-4, 64NXXX-5, 64NXXX-5 , 64NXXX-7, 64NXXX-A, 64NXXX-B, 64NXXX-N, 64NXXX-Y, 65NTPE-B, 65NTPX-2, 65NTPX-3, 65NTPX-4, 65NTPX-5, 65NTPX-6, 65NTPX-6, 65NTPX-6, 65NTPX-6, 65NTPX -A, 65NTPX-B, 65NTPX-N, 65NTPX-Y, 65NTXE-B, 65NTXX-2, 65NTXX-3, 65NTXX-4, 65NTXX-5, 65NTXX-6, 65NTXX-7, 65NTXX-A, 65NTXX-A, 65NTXX-A, 65NTXX-A , 65NTXX-N, 65NTXX-Y, 65NXPE-2, 65NXPE-3, 65NXPE-4, 65NXPE-5, 65NXPE-6, 65NXPE-7, 65NXPE-A, 65NXPE-B, 65NXPE-X, 65NXPE-X, 65NXPE-N -2, 65NXPX-3, 65NXPX-4, 65NXPX-5, 65NXPX-6, 65NXPX-7, 65NXPX-A, 65NXPX-B, 65NXPX-N, 65NXPX-Y, 65NXPX-Y, 65NXPX-Y, 2E5N6-XX , 65NXXE-5, 65NXXE-6, 65NXXE-7, 65NXXE-A, 65NXXE-B, 65NXXE-N, 65NXXE-Y, 65NXXX-2, 65NXXX-3, 65NXXX-4, 65NXXE-5, 665NXXX-5, 65NXXX-5, 65NXXX-5, 65NXXX-5, XXX -7, 65NXXX-A, 65NXXX-B, 65NXXX-N, 65NXXX-Y, 67NCDX-B, 67NCEP-B, 67NCEX-B, 67NCTP-B, 67NCTP-B-ECG3A, 67NCTX-B, 67NCXP-B -B, 67NSEP-B, 67NSEX-B, 67NSTP-B, 67NSTX-B, 67NSXP-B, 67NSXX-B, 67NXDX-B, 67NXEP-B, 67NXEX-B, 67NXECTP-B, 67NXTP-B,-67NXTP-B,-67NXTP-B -B, 67NXXP-B, 67NXXX-B, 68NCDX-B, 68NCEP-B, 68NCEX-B, 68NCTP-B, 68NCTX-B, 68NCXP-B, 68NCXX-B, 68NSEP-B, 68NSEX-B, 68NSEX-B, 68NSEX-B , 68NSTX-B, 68NSXP-B, 68NSXX-B, 68NXDX-B, 68NXEP-B, 68NXEX-B, 68NXTP-B, 68NXTX-B, 68NXXP-B, 68NXXX-B, 71WCETpot-B , 73CT-B, 74CE-B, 74CT-B, 74CX-B, 75CE-B, 75CT-B, 75CX-B, 901058, Semua, Atlas (Nellcor SpO₂), Siri Atlas 6200, Connex 6000 series, Encore 202EL Propaq 244, Propaq CS, Propaq LT, Tanda Vital Spot 42MOB, Tanda Vital Spot 42NOB, Tanda Vital Spot 42NTB-E1 Lihat Kurang |
Zoll | Siri E, Siri M, Siri R |
Spesifikasi Teknikal: | |
kategori | Penderia SpO₂ Pakai |
Pematuhan peraturan | FDA, CE, ISO 80601-2-61:2011, ISO10993-1, 5, 10:2003E, TUV, Mematuhi RoHS |
Penyambung Distal | Penyambung Ungu 9-Pin D-Sub Lelaki, Dwi Berkunci |
Teknologi SpO₂ | Nellcor OxiMax |
Saiz Pesakit | Bayi |
Jumlah Panjang Kabel(kaki) | 3 kaki(0.9m) |
Warna Kabel | putih |
Diameter Kabel | 3.2mm |
Bahan Kabel | PVC |
Bahan Sensor | Kain Anjal |
Tanpa lateks | ya |
Jenis Pembungkusan | kotak |
Unit Pembungkusan | 24pcs |
Berat Pakej | / |
Waranti | T/A |
steril | Pensterilan tersedia |
*Pengisytiharan: Semua tanda dagangan berdaftar, nama, model, dsb. yang dipaparkan dalam kandungan di atas adalah dimiliki oleh pemilik asal atau pengilang asal. Artikel ini hanya digunakan untuk menggambarkan keserasian produk MedLinket. Tiada niat lain! Semua di atas. maklumat adalah untuk rujukan sahaja, dan tidak boleh digunakan sebagai panduan untuk kerja institusi perubatan atau unit berkaitan. Jika tidak, sebarang akibat yang disebabkan oleh syarikat ini tiada kaitan dengan syarikat ini.