*Per ulteriori dettagli sul prodotto, controlla le informazioni di seguito o contattaci direttamente
Informazioni sull'ordineOEM | |
Produttore | OEM Parte # |
AMC | PR-E600-1011N (sensore microfoam), PR-E600-1013N (sensore microfoam) |
Conmetto | 2311 |
COVIDIEN> NELLCOR | D25 |
Draeger | 4534434 |
Envitec | DA-2411-1, DA-2211-1, DA-2271-1 |
GE Healthcare> Marquette | 2023217-001 |
Mediaid | CST034-2121 (18 in. / 45 cm) |
Philips | M1131A, 989803128531 |
Compatibilità: | |
Produttore | Modello |
Artema Sandw | Diascope |
Bionet | BM3, BM3 Plus |
Bionici | BPM-200 |
Biosys | BPM-200, Sentry |
COVIDIEN> NELLCOR | N-10, N-100, N-180, N-190, N-20, N-200, N-30, N-3000, N-390, N-395, N-6000, NPB-190, NPB-1950, NPB-290, NPB-295, NPB-3910, NPB-3920, NPB-3930, NPB-390, NPB-290, NPB-295, NPB-3910, NPB-3920, NPB-3930, NPB-500, NPB-290, NPB-295, NPB-3910, NPB-3920, NPB-3930, NPB-390, NPB-40, NPB-4000, NPB-75, Symphony N-3000 |
Datex ohmeda | Enguard CM5 |
Draeger | Cicerone, Infinity Delta XL, Infinity Gamma, Infinity Gamma XL, Infinity Kappa, Infinity Vista, Narkomed, Narkomed 4, Narkomed 6400, SC 6000, SC 7000, SC 8000, SC 9000XL, Vitalert 1000 |
Edan | H100B |
Fukuda Denshi | Dynascope DS-5100E, Dynascope DS-5300W |
GE Healthcare> Corometrics | 118, 120, 129, 188, 510, 511, 556 |
GE Healthcare> Critikon> Dinamap | 1000, 3000, 9710, 9720, compatto, Dinamap Select, moduli M-NSAT, MPS, Oxyshuttle, Plus, Pro 1000, Pro 300, Pro 300/400, Pro 400, Pro Series, Procare, SMU, SMV, Solar Serie |
GE Healthcare> Marquette | Cardioserv, Dash 2500, Dash 3000, Dash 4000, Dash 5000, Dash Series, Eagle 1000, Eagle 4000, Eagle Series, Hellige Eagle, Hellige SMK, Modulo PDM, Procare B40, Solar 8000, Solar 8000M, Tram 451, I/9500 |
Goldway | UT4000APRO, UT4000C, UT4000E, UT4000F, UT4000F PRO, UT6000A, VET 420A |
Huntleigh | SC1000 |
Infinium | Infitron II |
Invivo | 4500 Plus, 4500 Plus 3, Escort 100 Opt11a, Escort 300A, Escort II Opt30, M12, M12 (Nellcor spo₂), Millennia, Millennia 4500 Plus 2, Omega 1445, Omni-Trak TVS, Prism (Nellcor Spo₂), Sat Scout, Scout Scout |
Ivy Biomedical | 405A, 405D, 405p, 405T, VITAL-GUARD 450 CN |
Lumeon | Ossimetro portatile |
Mennen | Envoy, Horizon XL (Nelcor spo₂), MR 1300, MR 1300 Mercury 1200, Mercury 1200 |
Mindray> Datascope | Accutorr Plus, Accutorr V, DPM Central Station, DPM1, DPM2, DPM3, DPM4, DPM5, DPM6, DPM7, Duo, Expert, PM-50, PM-60, PM-60VET, Passport 2, Passport V, Passport XG, Spectrum, TRIO, VS 800, VS 900 |
Nihon Kohden | BSM-1102 Life Ampe EC, BSM-2300, BSM-2304 IPRO (Life Ampe I), BSM-4100, BSM-4102 Procyon LT (Life Ampe P), BSM-4104 Procyon (Life Scope P), BSM-4104A, BSM-4112 Procyon LT (Life P), Life P) Ambito P), BSM-4114A, BSM-5100, BSM-9510 Life Ampe m (Nellcor spo₂), OGS-2000 PocketCare (Nellcor spo₂) |
OMRON> Colin | BP-306, BP-508, BP-808, BP-88, BP-88S, macchina da stampa |
Pacetech | Serie VitalMax 800 (Black Nellcor spo₂) |
Philips | 78352C, 78354C, 78834C, 862108, 862231, 862439, 862474, 862478, 863063, 863069, 863073, 863077, 863266, C1, FM20, FM30, FM40, FM50A, M1020A M1025B, M1205A, M1350B, M1350C, M1722A, M1722A/B, M1722B, M1732A, M1732A/B, M1732B, M2475B, M2600A, M2601A, M2703A, M2704A, M27A, M3000A M3001A, M3001A A01, M3001A A01C06, M3001A A01C12, M3 ... Vedi di più |
Schiller | Argus CM8, Argus TM-7 |
Siemens | Sirecust 630, Sirecust 700, Modulo Sirem Spo₂ |
Smiths Medical> BCI | 3100, 3101, 3180, 3300, 3301, 3302, 3303, 3304, 3401, 6100, 9100, consulente, autocorr, mini torr, mini torr plus |
Spacelabs | 90351-0 / 6, 90465 (Nellcor spo₂), 90466 (Nellcor spo₂), 90467 (Nellcor spo₂), 90489 (Nellcor spo₂), 90496 /90369 /90367 UltraView (NellCor spo₂), 90651a-08, 90496 /90369 /90367 UltraView (NellCor spo₂) |
Stryker> Medtronic> Fisio Control | Lifepak 12 |
Suntech | Tutti i modelli tra cui NIBP 247b |
Teramax | 1000 |
Welch Allyn | Atlas (Nellcor spo₂), Micropaq (Nellcor spo₂), propaq 106-El, propaq 202-el, propaq 204-el, propaq 206-el, propaq cs (nellcor spo₂), spot vitali, segni vitali (non oxi-max) |
Specifiche tecniche: | |
Categoria | Sensori Spo₂ usa e getta |
Conformità normativa | FDA, CE, ISO 80601-2-61: 2011, ISO10993-1, 5, 10: 2003e, TUV, ROHS conforme |
Connettore distale | Connettore D-Sub maschile a 7 pin |
Tecnologia spo₂ | NellCor Oximax |
Dimensione del paziente | Adulto |
Lunghezza totale del cavo (FT) | 1,6 piedi (0,5 m) |
Colore del cavo | bianco |
Diametro del cavo | 3,2 mm |
Materiale via cavo | PVC |
Materiale del sensore | Microfoam 3M (adesivo) |
Senza lattice | SÌ |
Tipo di imballaggio | scatola |
Unità di imballaggio | 24pcs |
Peso del pacchetto | / |
Garanzia | N / A |
Sterile | Sterilizzazione disponibile |
*Dichiarazione: tutti i marchi registrati, i nomi, i modelli, ecc. Visualizzati nel contenuto di cui sopra sono di proprietà del proprietario originale o del produttore originale. Questo articolo viene utilizzato solo per illustrare la compatibilità dei prodotti MedLinket. Non c'è altra intenzione! Tutto quanto sopra. Le informazioni sono solo a riferimento e non devono essere utilizzate come guida per il lavoro di istituzioni mediche o unità correlate. Altrimenti, eventuali conseguenze causate da questa azienda non hanno nulla a che fare con questa azienda.